    Hone / Product / Curtain wall anchoring / High-strength chemical anchor

    HILTI HVAHigh-strength chemical anchor

    product description

    It is made of high-quality carbon steel or stainless steel and is suitable for cracked concrete and non-cracked concrete. It can be customized according to customer needs.

    Material

    Galvanized carbon steel / stainless steel


    Product advantages

    1. Chemical tube composition: vinyl resin, quartz particles, curing agent

    2. The glass tube is closed for packaging to facilitate visual inspection of the quality of the tube. After the glass is crushed, it acts as a fine aggregate.

    3. Anti-acid and alkali, heat, fire, low temperature sensitivity

    4. No expansion compressive stress on the substrate, suitable for heavy loads and various shock loads

    5. Installation spacing and margin requirements are small

    6. Quick installation, rapid curing, does not affect the construction progress

    7. Wide range of construction temperatures


    Applicable substrate

    1. Planting of new concrete without pre-embedded steel

    2. Applicable to the reinforcement and transformation project, the rooting of the screw and steel in the substrate

    3. Various equipment, pipeline installation, curtain wall bracket fixing

    4. Bonding and fixing of wooden members, plastic members and metal members

    5. Applicable to the reinforcement of railways, highways, bridges, water conservancy renovation and expansion projects

    6. Billboards, tunnel lines, elevated road baffles and guardrails

    7. Suitable for all kinds of curtain wall stone hanging brackets fixed


    Construction process

    1, substrate drilling

    Drill the substrate with professional drilling tools and impact hammers according to the dimensions required by the design drawings

    2, cleaning the hole

    Use the compressed gas to blow out the dust in the hole, and then use a special brush to clean the dust attached to the inner wall of the hole.

    3, put the medicine tube

    Check the fluidity of the resin by hand or visual inspection. After confirming, insert the drug into the bottom of the hole.

    4, screw into the screw

    Before the screw is buried, there is a 45° chamfer, the rear end is screwed in, the hex nut is driven by the power tool and screwed into the bottom of the hole.

    5, curing curing

    Allow the anchoring gel to solidify naturally, the curing time is based on the temperature reference curing schedule, and the screw should not be rotated or tapped during the curing period.


    Storage

    Storage period of 12 months, stored in a cool dry place


    Installation data

    model

    Drilling diameter

    Effective depth

    Maximum anchoring thickness

    Minimum substrate thickness

    Installation torque

    (KN)
    Hef's influence coefficient on Vrd, cp (K)


    Concrete vertebral body destructionConcrete splitting failure

    Total length of screw

    Critical spacing

    Critical margin

    Minimum spacingMinimum marginCritical spacingCritical margin
    M8×110108015120122.02401204848240120110
    M10×130129020.5130202.02701356060270135130
    M12×1601411025160402.03301657272330165160
    M16×1901812533175602.03751909696375188190
    M20×26025170652201002.0510255120120510255260
    M24×30028210652701602.0630315144144630315300
    M30×3803528066.53402402.0840420180180840420380

    1. The table installation data unit is mm, technical parameter unit kN

    2. The table data is based on C20/C25 substrate concrete. If the grade of the substrate changes, the requirements of the technical department and the design drawings should be followed.

    3. Form stainless steel 316 is A4-70 stainless steel

    4. The table design load contains the material safety factor.

    5. Form data is suitable for: correct installation, no margin, no spacing effect, minimum substrate thickness

    6. For products not listed in the table, please refer to JGJ145-2013 Technical Specification for Post-Anchage of Concrete Structures. According to the calculation method of the ultimate state of bearing capacity, the corresponding data is obtained. For details, please consult the technical department of Shibang (Shanghai) Industrial Co., Ltd.


    Technical Parameters


    High-strength chemical anchor bolt technical parametersM8×110M10×130M12×160M16×190M20×260M24×300M30×380
    Standard value / design valueStandard value / design valueStandard value / design valueStandard value / design valueStandard value / design valueStandard value / design valueStandard value / design value
    Non-cracking concrete tensile parameters5.814.4/9.419.7/12.832.5/21.167.4/44.2101.8/67.0143.1/94.4231.0/153
    8.822.9/15.131.2/20.551.6/33.869.5/45.6109.9/60.3150.6/82.8231.0/153
    30414.4/5.019.7/6.732.5/11.167.4/23.3101.8/35.3143.149.6231.0/153
    31620.0/10.527.3/14.345.3/15.669.5/38.0109.9/60.3150.6/82.8/
    Non-cracking concrete shear parameters5.85.6/4.77.7/6.412.7/10.526.5/22.140.2/33.557.7/47.298.1/81.8
    8.89.0/7.512.3/10.320.3/16.942.4/35.364.3/53.690.6/75.5157.0/130.8
    3043.0/2.54.0/3.46.7/5.613.9/11.621.1/17.629.7/24.751.5/42.9
    3166.3/5.38.6/7.214.3/11.929.8/24.845.2/37.763.7/53.1/
    Cracked concrete tensile parameters5.814.4/9.419.7/12.832.5/21.150.0/27.278.8/43.1108.0/59.2165.4/91.1
    8.822.9/15.131.2/20.541.1/22.450.0/27.278.8/43.1108.0/59.2165.4/91.1
    30414.4/5.019.7/6.732.5/11.150.0/17.278.8/28.4108.0/41.3165.4/91.1
    31620.0/10.527.3/14.341.1/14.150.0/27.278.8/43.1108.0/59.2/
    Cracking concrete shear parameters5.85.6/4.77.7/6.412.7/10.526.5/22.140.2/33.557.7/47.298.1/81.8
    8.89.0/7.512.3/10.320.3/16.942.4/35.364.3/53.690.6/75.5157.0/130.8
    3043.0/2.54.0/3.46.7/5.613.9/11.621.1/17.629.7/24.751.5/42.9
    3166.3/5.38.6/7.214.3/11.929.8/24.845.2/37.763.7/53.1/


    1. The table installation data unit is mm, technical parameter unit kN

    2. The table data is based on C20/C25 substrate concrete. If the grade of the substrate changes, the requirements of the technical department and the design drawings should be followed.

    3. Form stainless steel 316 is A4-70 stainless steel

    4. The table design load contains the material safety factor.

    5. Form data is suitable for: correct installation, no margin, no spacing effect, minimum substrate thickness

    6. For products not listed in the table, please refer to JGJ145-2013 Technical Specification for Post-Anchage of Concrete Structures. According to the calculation method of the ultimate state of bearing capacity, the corresponding data is obtained. For details, please consult the technical department of Shibang (Shanghai) Industrial Co., Ltd.


    施邦客服人員會一對一竭心為您服務

    信任由一次愉快的交談開始

    咨詢熱線:021-3636 7599

    Online Free call

    Support hotline

    021-3636 7599
    Message Code

    Scan code attention

    Top
    主站蜘蛛池模板: 蜜桃成熟时2005| 无码精品久久久天天影视| 国产精品视频网站你懂得| 欧美日韩精品视频一区二区| 污污动漫在线观看| 欧美日韩一区二区在线视频| 四虎影视在线影院在线观看| 亚洲人成色777777在线观看| jizzjizz视频| 无人视频免费观看免费视频| 免费的a级毛片| 日本a∨在线观看| 中文国产成人精品久久96| 欧美日韩国产在线人成| 久久久久久久99精品免费观看| 国产乱人免费视频| 国内精品久久久人妻中文字幕| 成年美女黄网站色大片免费看| 小sao货水好多真紧h视频| 麻豆md传媒md00中国| 亚洲综合图片小说区热久久| 日韩字幕一中文在线综合| 国产香蕉在线视频一级毛片| 精品国产一区二区三区不卡| 欧美一区二区久久精品| 亚洲电影中文字幕| 国产69精品久久久久9999| 国产一卡2卡3卡4卡公司在线| 免费观看国产小粉嫩喷水| 国产精品成人va在线播放| 1000部拍拍拍18免费网站| 久久精品国产精品亚洲毛片| 国产成人免费av片在线观看| 制服丝袜怡红院| 好男人www社区| 色哟哟视频在线观看网站| 一级毛片大全免费播放| 激情小说视频在线观看| 精品少妇无码AV无码专区| 丰满肥臀风间由美357在线| 黄色网站在线免费观看|